Performance analysis of aluminium Thermosyphon at Various Inclination
Author(s):
Vinod Heeraram Choudhary, Piyush Vijay Chaudhari, Apurv Ravindra Chaudhari, Vaibhav Madhavrao Dahale
Keywords:
Aluminium Thermosyphon
Abstract
Electronic Devices, Power plants, etc. have losses in form of heat and to increase their efficiency it is essential to liberate heat from them at high rates. A model is being developed to investigate the performance of two phase close thermosyphon. A aluminium thermosyphon of length 350 mm and internal and external diameters of 17.5 mm and 19.5 mm is used for experiment. The thermosyphon charged with acetone with filling ratio of 30% is investigated. The performance analysis was conducted at inclination angles of 30º, 50º, 70º and 90º. And heat input of 50 W to 250 W was given at evaporator section.