PARTIAL REPLACEMENT OF RIVER AND WITH ROBO SAND

  • Unique Paper ID: 144874
  • Volume: 4
  • Issue: 5
  • PageNo: 151-156
  • Abstract:
  • The most frequently used fine aggregate across world is river sand. River sand is costly due to undue cost of transportation from natural sources. Also large scale reduction of the source creates environmental problems. As ecological, transportation and other constraint formulate the availability and use of river sand less good-looking. A alternative or replacement product for concrete industry needs to be found. The main parameter investigated in this study is M30 grade concrete with replacement of sand by robosand by 0, 10, 20, 50, 70 and 100%. This paper presents a detailed experimental study on compressive strength, split tensile strength 3, 7 and 28 days on hardened concrete and slump cone test and compaction factor test on fresh concrete.

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{144874,
        author = {Y.SOMBABU and K.PRABHAKAR and P.MADHURI},
        title = {PARTIAL REPLACEMENT OF RIVER AND WITH ROBO SAND},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {4},
        number = {5},
        pages = {151-156},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=144874},
        abstract = {The most frequently used fine aggregate across world is river sand. River sand is costly due to undue cost of transportation from natural sources. Also large scale reduction of the source creates environmental problems. As ecological, transportation and other constraint formulate the availability and use of river sand less good-looking. A alternative or replacement product for concrete industry needs to be found. The main parameter investigated in this study is M30 grade concrete with replacement of sand by robosand by 0, 10, 20, 50, 70 and 100%. This paper presents a detailed experimental study on compressive strength, split tensile strength 3, 7 and 28 days on hardened concrete and slump cone test and compaction factor test on fresh concrete.},
        keywords = {Ecological, Robosand, Compressive},
        month = {},
        }

Cite This Article

  • ISSN: 2349-6002
  • Volume: 4
  • Issue: 5
  • PageNo: 151-156

PARTIAL REPLACEMENT OF RIVER AND WITH ROBO SAND

Related Articles