Simulation Of LCL Filter For Shunt Active Power Filter In Single Phase Power Line Using Matlab

  • Unique Paper ID: 142389
  • Volume: 2
  • Issue: 1
  • PageNo: 53-62
  • Abstract:
  • Among all the filter the LCL filter is more suited for high-power low-switching –frequency application than the L filters due to its better attenuation characteristics on high frequency .But LCL filter parameter design is more complex due to the effect of high -frequency harmonic current as well as the controller response performance of the converter. In this paper LCL filter is been connected in the single phase supply,and different parameters of the system is been analysis.The control technique used in this paper is SPWM (sinosidual pulse width modulation). The effectiveness of the filter is proved by the simulation result and Expermental result of the single phase system is given at the End of this paper
add_icon3email to a friend

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{142389,
        author = {Devesh Raj Saxena and A.R.Soman},
        title = {Simulation Of LCL Filter For Shunt Active Power Filter In Single Phase Power Line Using Matlab},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {2},
        number = {1},
        pages = {53-62},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=142389},
        abstract = {Among all the filter the LCL filter is  more suited for high-power low-switching –frequency application than the L filters due to its better attenuation characteristics on high frequency .But LCL filter parameter design is more complex due to the effect of high -frequency harmonic current as well as the controller response performance of the converter. In this paper LCL filter is been connected in the single phase supply,and  different parameters of the system is been analysis.The control technique used in this paper is SPWM (sinosidual pulse width modulation). The effectiveness of the filter is  proved by the simulation result  and Expermental result of the single  phase  system is given at the End of this paper},