REDUCED SWITCHING LOSS AC/DC/AC CONVERTER WITH FEED FORWARD CONTROL

  • Unique Paper ID: 143933
  • Volume: 3
  • Issue: 4
  • PageNo: 53-61
  • Abstract:
  • This paper presents a novel simplified pulse width modulation (PWM) strategy for the bidirectional ac/dc single phase converter in a micro grid system. Then, the operation mechanism of the novel simplified PWM is clearly explained. The number of switching’s of the proposed simplified PWM strategy is one fourth that of the conventional unipolar PWM and bipolar PWM. Based on the novel simplified PWM strategy, a feasible feed forward control scheme is developed to achieve better rectifier mode and inverter mode performance compared with the conventional dual loop control scheme. The proposed simplified PWM strategy with the proposed feed forward control scheme has lower total harmonic distortion than the bipolar PWM and higher efficiency than both unipolar and bipolar PWMs. Furthermore, the proposed simplified PWM operated in the inverter mode also has larger available fundamental output voltage v_ab than both the unipolar and bipolar PWMs.
add_icon3email to a friend

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{143933,
        author = {Avuluri.Saritha reddy and T.naga durga},
        title = {REDUCED SWITCHING LOSS AC/DC/AC CONVERTER WITH FEED FORWARD CONTROL},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {3},
        number = {4},
        pages = {53-61},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=143933},
        abstract = {This paper presents a novel simplified pulse width modulation (PWM) strategy for the bidirectional ac/dc single phase converter in a micro grid system. Then, the operation mechanism of the novel simplified PWM is clearly explained. The number of switching’s of the proposed simplified PWM strategy is one fourth that of the conventional unipolar PWM and bipolar PWM. Based on the novel simplified PWM strategy, a feasible feed forward control scheme is developed to achieve better rectifier mode and inverter mode performance compared with the conventional dual loop control scheme. The proposed simplified PWM strategy with the proposed feed forward control scheme has lower total harmonic distortion than the bipolar PWM and higher efficiency than both unipolar and bipolar PWMs. Furthermore, the proposed simplified PWM operated in the inverter mode also has larger available fundamental output voltage v_ab than both the unipolar and bipolar PWMs.},