PERFORMANCE ANALYSIS OF VCR SYSTEM BY USING HYDROCARBON REFRIGERANTS

  • Unique Paper ID: 144605
  • PageNo: 127-132
  • Abstract:
  • Hydrocarbon refrigerant is a natural refrigerant. It is used to avoid the difficulties caused by conventional cfc refrigerants relatively such as R12, R22, R134a are ODP&GWP. In this paper the performance analysis of VCR system is done by using HC refrigerants and also compares that performance with CFC refrigerants. There are three combinations of HC refrigerants such as R290 (60%) R600a (20%) R1270 (20%), R290 (20%) R600a (60%) R1270 (20%) and R290 (20%) R600a (20 %) R1270 (60%) are used to analysis the heat transfer rate and cycle performance .Also the co efficient of performance of the refrigeration system is analysed for various evaporating temperature.
add_icon3email to a friend

Copyright & License

Copyright © 2026 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{144605,
        author = {R.Dhananjeyan and S. Senthilkumar and M. Thilak and M.Ganesh karthikeyan},
        title = {PERFORMANCE ANALYSIS OF VCR SYSTEM BY USING HYDROCARBON REFRIGERANTS},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {4},
        number = {1},
        pages = {127-132},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=144605},
        abstract = {Hydrocarbon refrigerant is a natural refrigerant. It is used to avoid the difficulties caused by conventional cfc refrigerants relatively such as R12, R22, R134a are ODP&GWP. In this paper the performance analysis of VCR system is done by using HC refrigerants and also compares that performance with CFC refrigerants. There are three combinations of HC refrigerants such as R290 (60%) R600a (20%) R1270 (20%), R290 (20%) R600a (60%) R1270 (20%) and R290 (20%) R600a (20 %) R1270 (60%) are used to analysis the heat transfer rate and cycle performance .Also the co efficient of performance of the refrigeration system is analysed for various evaporating temperature. },
        keywords = {Chloro fluoro carbon (CFC), Hydro Carbon (HC), VCR system, GWP, ODP. },
        month = {},
        }

Cite This Article

R.Dhananjeyan, , & Senthilkumar, S., & Thilak, M., & karthikeyan, M. (). PERFORMANCE ANALYSIS OF VCR SYSTEM BY USING HYDROCARBON REFRIGERANTS. International Journal of Innovative Research in Technology (IJIRT), 4(1), 127–132.