PERFORMANCE ANALYSIS ON DOUBLE PIPE HEAT EXCHANGER USING WIRE COILED AND PIN WIRE COILED TURBULATOR INSERTS

  • Unique Paper ID: 144608
  • PageNo: 188-194
  • Abstract:
  • The heat exchanger is an important device in almost all of the mechanical industries as in case of process industries it is key element. Thus from long time many researchers in this area are working to improve the performance of these heat exchangers in terms of heat transfer rate, keeping pressure drop in limit by using various techniques. This project work deals with of such techniques keeping focus on passive augmentation techniques used in heat exchangers. Here the wire coiled turbulator and pin wire coiled turbulator are used to enhance the heat transfer rate in the double pipe heat exchanger by changing the flow of a liquid. Tests to be conducted at various mass flow rates by controlling the flow control valve, for the following valve opens (25%, 50%, 75%, 100% valve open). Results may indicate that the heat transfer rate enhances inversely with the pitch of the wire coiled turbulator and directly proportional to the mass flow rate.
add_icon3email to a friend

Copyright & License

Copyright © 2026 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{144608,
        author = {S.Shanmugapriya and M.Ganesh karthikeyan and Dr.M.Prabakar and S. Senthilkumar},
        title = {PERFORMANCE ANALYSIS ON DOUBLE PIPE HEAT EXCHANGER USING WIRE COILED AND PIN WIRE COILED TURBULATOR INSERTS},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {4},
        number = {1},
        pages = {188-194},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=144608},
        abstract = {The heat exchanger is an important device in almost all of the mechanical industries as in case of process industries it is key element. Thus from long time many researchers in this area are working to improve the performance of these heat exchangers in terms of heat transfer rate, keeping pressure drop in limit by using various techniques. This project work deals with of such techniques keeping focus on passive augmentation techniques used in heat exchangers. Here the wire coiled turbulator and pin wire coiled turbulator are used to enhance the heat transfer rate in the double pipe heat exchanger by changing the flow of a liquid. Tests to be conducted at various mass flow rates by controlling the flow control valve, for the following valve opens (25%, 50%, 75%, 100% valve open). Results may indicate that the heat transfer rate enhances inversely with the pitch of the wire coiled turbulator and directly proportional to the mass flow rate.},
        keywords = {Double pipe heat exchanger, Plain Tube, Wire coiled turbulator inserts, Pin wire coiled turbulator   inserts, Pressure drop, Friction Co-efficient.},