Advanced five-Level Cascaded H�bridge (CHB) Inverter as Distribution Static Compensator (DSTATCOM) for Power Quality Improved

  • Unique Paper ID: 145196
  • PageNo: 677-681
  • Abstract:
  • This paper presents an investigation of five-Level Cascaded H–bridge (CHB) Inverter as Distribution Static Compensator (DSTATCOM) in Power System (PS) for compensation of reactive power and harmonics. The advantages of CHB inverter are low harmonic distortion, reduced number of switches and suppression of switching losses. The DSTATCOM helps to improve the power factor and eliminate the Total Harmonics Distortion (THD) drawn from a Non-Liner Diode Rectifier Load (NLDRL). The D-Q reference frame theory is used to generate the reference compensating currents for DSTATCOM while Proportional and Integral (PI) control is used for capacitor dc voltage regulation. A CHB Inverter is considered for shunt compensation. We are using Sinusoidal Pulse Width Modulation (SPWM) technique. The results are obtained through Mat lab /Simulink.

Copyright & License

Copyright © 2026 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{145196,
        author = {Ganesh Dnyanoba Shingade and Sandip S.Rathod and Amol P.Chopade and Prashant B Pawar},
        title = {Advanced five-Level Cascaded H�bridge (CHB) Inverter as Distribution Static Compensator (DSTATCOM) for Power Quality Improved },
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {4},
        number = {7},
        pages = {677-681},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=145196},
        abstract = {This paper presents an investigation of five-Level Cascaded H–bridge (CHB) Inverter as Distribution Static Compensator (DSTATCOM) in Power System (PS) for compensation of reactive power and harmonics. The advantages of CHB inverter are low harmonic distortion, reduced number of switches and suppression of switching losses. The DSTATCOM helps to improve the power factor and eliminate the Total Harmonics Distortion (THD) drawn from a Non-Liner Diode Rectifier Load (NLDRL). The D-Q reference frame theory is used to generate the reference compensating currents for DSTATCOM while Proportional and Integral (PI) control is used for capacitor dc voltage regulation. A CHB Inverter is considered for shunt compensation. We are using Sinusoidal Pulse Width Modulation (SPWM) technique. The results are obtained through Mat lab /Simulink.},
        keywords = {DSTATCOM, (SPWM), CHB
multilevel inverter.
},
        month = {},
        }

Cite This Article

Shingade, G. D., & S.Rathod, S., & P.Chopade, A., & Pawar, P. B. (). Advanced five-Level Cascaded H�bridge (CHB) Inverter as Distribution Static Compensator (DSTATCOM) for Power Quality Improved . International Journal of Innovative Research in Technology (IJIRT), 4(7), 677–681.

Related Articles