A Comparative Seismic Study on Elevated Storage Tank for different Frame conditions- Literature Review

  • Unique Paper ID: 145543
  • PageNo: 310-313
  • Abstract:
  • Various formulaes and methods were formed to study the behaviour of Elevated water storage tanks. In dynamic analysis, the elevated water tank is analysed for time history analysis and response spectrum analysis. For time history analysis consider time acceleration values of past earthquake and for dynamic analysis, use seismic formulaes, magnitude, particular zone, damping, importance factor and reduction factors to study the behaviour of structures. Various staging patters were analysed to increase stiffness and to provide economy in structure. Cross bracings were provided to increase strength against lateral forces.Study number of models in different zones and in different soil conditions. Various time history ground motions were taken to study behaviour of structure and frame.

Copyright & License

Copyright © 2026 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{145543,
        author = {Arbaj Khan Demrot and Rashmi Sakalle and Nitin Tiwari},
        title = {A Comparative Seismic Study on Elevated Storage Tank for different Frame conditions- Literature Review},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {4},
        number = {10},
        pages = {310-313},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=145543},
        abstract = {Various formulaes and methods were formed to study the behaviour of Elevated water storage tanks. In dynamic analysis, the elevated water tank is analysed for time history analysis and response spectrum analysis. For time history analysis consider time acceleration values of past earthquake and for dynamic analysis, use seismic formulaes, magnitude, particular zone, damping, importance factor and reduction factors to study the behaviour of structures. Various staging patters were analysed to increase stiffness and to provide economy in structure. Cross bracings were provided to increase strength against lateral forces.Study number of models in different zones and in different soil conditions. Various time history ground motions were taken to study behaviour of structure and frame.},
        keywords = {dynamic, elevated tank, seismic, time history, bracing, damping, stiffness},
        month = {},
        }

Cite This Article

Demrot, A. K., & Sakalle, R., & Tiwari, N. (). A Comparative Seismic Study on Elevated Storage Tank for different Frame conditions- Literature Review. International Journal of Innovative Research in Technology (IJIRT), 4(10), 310–313.