Experimental Analysis Of Vapour Compression Refrigeration System With Subcooling By Using R-134a, R-12, R-717 Refrigerent

  • Unique Paper ID: 146108
  • PageNo: 1406-1411
  • Abstract:
  • basically Cop can be increased either by increasing the refrigeration effect or by decreasing the power required in simple vapour compression refrigeration system . so we Need to modify the system . The subcooling is done after condenser by using heat exchanger . By subcooling the condenser temperature reduces and refrigeration effect increases with the help of these three refrigerant R-134a, R-12,R-717 by performing experiment not only we recorded their result but other parameter also such as Cop, refrigeration effect, power required, volumetric efficiency, percentage increment or decrement in Cop . The main focus of this paper was to calculate the performance of VCRS cycle with the help of heat exchanger by using three refrigerant such as R-134a, R-717,R-12 .
add_icon3email to a friend

Copyright & License

Copyright © 2026 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{146108,
        author = {Shree singh karoria and Ravindra Randa},
        title = {Experimental Analysis Of Vapour Compression Refrigeration System With Subcooling By Using R-134a, R-12, R-717 Refrigerent},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {4},
        number = {11},
        pages = {1406-1411},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=146108},
        abstract = {basically Cop can be increased either by increasing the refrigeration effect or by decreasing the power required in simple vapour compression refrigeration system . so we Need to modify the system . The subcooling is done after condenser by using heat exchanger . By subcooling the condenser temperature reduces and refrigeration effect increases with the help of these three refrigerant R-134a, R-12,R-717 by performing experiment not only we recorded their result but other parameter also such as Cop, refrigeration effect, power required, volumetric efficiency, percentage increment or decrement in Cop . The main focus of this paper was to calculate the performance of VCRS cycle with the help of heat exchanger by using three refrigerant such as R-134a, R-717,R-12 .},
        keywords = {Vapour compression refrigeration cycle , compressor , heat exchanger ,condenser ,refrigerants},
        month = {},
        }