Behavior of Precast Beam-Column Junction and RC (Cast-in-situ) Beam-Column Junction on Experimental Based Study

  • Unique Paper ID: 146978
  • Volume: 5
  • Issue: 2
  • PageNo: 685-690
  • Abstract:
  • In this study, we have design a junction of Beam-Column RC and Precast and then applying a different types of load on the junction specimen. Comparison between the load-deflection on both cases, Comparison between the exterior and interior joint with transverse reinforcement details as per IS 13920-1993 and SP16.Comparison between the previous lists of experimental work. The effect of axial load on the behaviour of joint is also considered in this study. That type of experimental work on precast beam-column junction has been never done at the plant of “Precast India Infrastructure Limited”. Comparison between the manually work which is done by the code of IS 13920-1993,IS 1893 part 1 – 2002 ,SP 16 and others. Comparison between the chemicals of precast members which is applied in the junction (Fosrok & Ultratech Power Grouting).

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{146978,
        author = {Rishabh R Shukla and Prof. Girish V. Joshi},
        title = {Behavior of Precast Beam-Column Junction and RC (Cast-in-situ) Beam-Column Junction on Experimental Based Study},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {5},
        number = {2},
        pages = {685-690},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=146978},
        abstract = {In this study, we have design a junction of Beam-Column RC and Precast and then applying a different types of load on the junction specimen. Comparison between the load-deflection on both cases, Comparison between the exterior and interior joint with transverse reinforcement details as per IS 13920-1993 and SP16.Comparison between the previous lists of experimental work. The effect of axial load on the behaviour of joint is also considered in this study. That type of experimental work on precast beam-column junction has been never done at the plant of “Precast India Infrastructure Limited”. Comparison between the manually work which is done by the code of IS 13920-1993,IS 1893 part 1 – 2002 ,SP 16 and others. Comparison between the chemicals of precast members which is applied in the junction (Fosrok & Ultratech Power Grouting).

},
        keywords = {Precast Beam-Column junction, wooden kiln, static hydraulic machines etc.},
        month = {},
        }

Related Articles