Measurement and Investigation of PCC point Harmonics in Grid Connected Photovoltaic system

  • Unique Paper ID: 148059
  • Volume: 5
  • Issue: 12
  • PageNo: 197-200
  • Abstract:
  • This paper work presents analysis and harmonic measurement at point of common coupling (PCC) when Photovoltaic (PV) system is connected to utility grid. Use of power electronic convertors while integrating PV to grid may introduce harmonics, due this power electronic convertor deteriorates power quality. Photovoltaic (PV) system is connected to grid via 3-phase 3-level voltage source converter (VSC). The maximum power point tracking (MPPT) is implemented using incremental conductance technique (IC). An AC/DC/AC IGBT based SPWM converter is considered for study. THD measurement of the different possible cases of PV system integrated to grid at PCC has been carried out in MATLAB/Simulink environment. Finally, harmonic mitigation and power quality improvement at PCC using passive filter and control technique of complete system is proposed and proved by different simulation results.

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{148059,
        author = {Bhushan Tarachand Lanjewar and Prof. Nagmanaj Pathan},
        title = {Measurement and Investigation of PCC point Harmonics in Grid Connected Photovoltaic system},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {5},
        number = {12},
        pages = {197-200},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=148059},
        abstract = {This paper work presents analysis and harmonic measurement at point of common coupling (PCC) when Photovoltaic (PV) system is connected to utility grid. Use of power electronic convertors while integrating PV to grid may introduce harmonics, due this power electronic convertor deteriorates power quality. Photovoltaic (PV) system is connected to grid via 3-phase 3-level voltage source converter (VSC). The maximum power point tracking (MPPT) is implemented using incremental conductance technique (IC). An AC/DC/AC IGBT based SPWM converter is considered for study. THD measurement of the different possible cases of PV system integrated to grid at PCC has been carried out in MATLAB/Simulink environment. Finally, harmonic mitigation and power quality improvement at PCC using passive filter and control technique of complete system is proposed and proved by different simulation results.},
        keywords = {MPPT, Power Quality (PQ), Renewable Energy Sources(RES), THD Measurement, Utility Grid.},