STUDY ON EFFECT OF MAGNETIC FIELD TREATED WATER ON FRESH AND HARDENED CONCRETE PROPERTIES

  • Unique Paper ID: 149365
  • Volume: 6
  • Issue: 12
  • PageNo: 84-88
  • Abstract:
  • This study involves the investigation of magnetic water on the workability, consistency, compaction factor and compressive strength of concrete. The water is magnetized with the help of 0.5hp motor having an intensity of 0.9 Tesla at its inlet pipe. Both the physical and chemical properties of normal water and magnetic water have to be studied. Concrete samples are then prepared by using magnetic water and ordinary water for mixing and cured with ordinary tap water. The concrete cubes are casted for M20 grade and tested for 7, 14, 21 and 28 days respectively. The main scope of the study is to improve the qualities of normal tap water as per Indian standards after magnetisation and to reduce the water cement ratio thereby reducing the consumption of cement content and curing days.

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{149365,
        author = {M. Divya},
        title = {STUDY ON EFFECT OF MAGNETIC FIELD TREATED WATER ON FRESH AND HARDENED CONCRETE PROPERTIES},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {6},
        number = {12},
        pages = {84-88},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=149365},
        abstract = {This study involves the investigation of magnetic water on the workability, consistency, compaction factor and compressive strength of concrete. The water is magnetized with the help of 0.5hp motor having an intensity of 0.9 Tesla at its inlet pipe. Both the physical and chemical properties of normal water and magnetic water have to be studied. Concrete samples are then prepared by using magnetic water and ordinary water for mixing and cured with ordinary tap water. The concrete cubes are casted for M20 grade and tested for 7, 14, 21 and 28 days respectively. The main scope of the study is to improve the qualities of normal tap water as per Indian standards after magnetisation and to reduce the water cement ratio thereby reducing the consumption of cement content and curing days.},
        keywords = {Magnetic Water, Workability, Compressive Strength, Curing Ages},