Analysis of G+15 High Rise Buildings by Using E-tabs for Various Frame Sections In Zone II and Zone III

  • Unique Paper ID: 154994
  • PageNo: 988-997
  • Abstract:
  • ETABS stand for Extended Three Dimensional Analysis of Building Systems.ETABS integrates every aspect of the engineering design process. In the present situations of construction industry,the buildings that are being constructed regaining significance,in general ,those wise the best possible outcomes which are referred to members like beams and columns in multi storeys R.C structures. This software mainly used for structures like high-rise buildings,steel and concrete structures. The paper aims to analyze a high-rise building of 15 floors (G+15) by considering seismic, dead and live loads. The design criteria for high-rise buildings are strength, serviceability and stability. The version of the software used is ETABS 2016.In the present study, we are mainly determining the effects of lateral loads on moments, shear force, axial force, base shear, maximum displacement and tensile forces on structural system are subjected and also comparing the results of zone 2 and zone 3.

Copyright & License

Copyright © 2026 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{154994,
        author = {Pawan R.Thakare},
        title = {Analysis of G+15 High Rise Buildings by Using E-tabs for Various Frame Sections In Zone II and Zone III},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {8},
        number = {12},
        pages = {988-997},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=154994},
        abstract = {ETABS stand for Extended Three Dimensional Analysis of Building Systems.ETABS integrates every aspect of the engineering design process. In the present situations of construction industry,the buildings that are being constructed  regaining significance,in general ,those wise the best possible outcomes which are referred to members like beams and columns in multi storeys R.C structures. This software mainly used for structures like high-rise buildings,steel and concrete structures. The paper aims to analyze a high-rise building of 15 floors (G+15) by considering seismic, dead and live loads. The design criteria for high-rise buildings are strength, serviceability and stability. The version of the software used is ETABS 2016.In the present study, we are mainly determining the effects of lateral loads on moments, shear force, axial force, base shear, maximum displacement and tensile forces on structural system are subjected and also comparing the results of zone 2 and zone 3.},
        keywords = {ETABS; Seismic Analysis; High-rise buildings.},