Total Harmonic Reduction By Multi Pulse Converters

  • Unique Paper ID: 156077
  • Volume: 9
  • Issue: 2
  • PageNo: 930-935
  • Abstract:
  • The issue of power quality now a days is a major concerned area of research in the power sector. This is because of awareness created by IEEE 519-1992(Institute of Electrical & Electronics Engineering) like standards which implies the utility as well as consumers of electric power to improve quality. With the advancement in the technology now it is possible to keep power sector free from pollution. This paper has given an idea that power quality can be improved with development of multi pulse converter, Here 6,12,24,48 pulse converters have been modeled and simulated in MATLAB software. The multi pulse converters are tested for different loads and comparison is also presented among them which clearly shows that the problem of power quality is reduced considerably.

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{156077,
        author = {Dr. Santosh Kumar Vishwakarma(Madhyanchal Professional and Dr. Shiv Kumar Sonkar(Madhyanchal Professional University)},
        title = {Total Harmonic Reduction By Multi Pulse Converters},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {9},
        number = {2},
        pages = {930-935},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=156077},
        abstract = {The issue of power quality now a days is a major concerned area of research in the power sector. This is because of awareness created by IEEE 519-1992(Institute of Electrical & Electronics Engineering) like standards which implies the utility as well as consumers of electric power to improve quality. With the advancement in the technology now it is possible to keep power sector free from pollution. This paper has given an idea that power quality can be improved with development of multi pulse converter, Here 6,12,24,48 pulse converters have been modeled and simulated in MATLAB software. The multi pulse converters are tested for different loads and comparison is also presented among them which clearly shows that the problem of power quality is reduced considerably.},
        keywords = {THD, Multi pulse converter, Power Quality, Harmonics, High Power Drives.},
        month = {},
        }

Cite This Article

  • ISSN: 2349-6002
  • Volume: 9
  • Issue: 2
  • PageNo: 930-935

Total Harmonic Reduction By Multi Pulse Converters

Related Articles