NON-INVASIVE GLUCOMETER

  • Unique Paper ID: 158716
  • Volume: 9
  • Issue: 10
  • PageNo: 579-583
  • Abstract:
  • This project is focused on developing a non-invasive, low-cost method for monitoring blood glucose levels using near-infrared (NIR) light. The project utilizes a NIR light source to penetrate the skin and detect glucose molecules in the blood vessels. The intensity ratio between absorbed NIR in glucose molecules and scattered NIR light in the photodetector is used to calculate the glucose level. The measured glucose level is displayed on an LCD screen and transmitted wirelessly to a smartphone app using the Blynk platform. This project has the potential to revolutionize blood glucose monitoring for individuals with diabetes, making the process easier, more accessible, and less painful.

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{158716,
        author = {Dr. B. Sankaragomathi and G. Gopi and K. Kowshikkumar and J. Manoj Kumar and T. Prakash Pandian},
        title = {NON-INVASIVE GLUCOMETER},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {9},
        number = {10},
        pages = {579-583},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=158716},
        abstract = {This project is focused on developing a non-invasive, low-cost method for monitoring blood glucose levels using near-infrared (NIR) light. The project utilizes a NIR light source to penetrate the skin and detect glucose molecules in the blood vessels. The intensity ratio between absorbed NIR in glucose molecules and scattered NIR light in the photodetector is used to calculate the glucose level. The measured glucose level is displayed on an LCD screen and transmitted wirelessly to a smartphone app using the Blynk platform. This project has the potential to revolutionize blood glucose monitoring for individuals with diabetes, making the process easier, more accessible, and less painful.},
        keywords = {Buzzer, Lcd, Node-MCU, NIR Light,, Photodetector},