PARTIAL REPLACEMENT OF FINE AGGREGATE BY COPPER SLAG

  • Unique Paper ID: 165097
  • Volume: 11
  • Issue: 1
  • PageNo: 491-494
  • Abstract:
  • This project presents the usage of Copper Slag for the partial replacement of Fine aggregate the experimental procedure will be conducted for the replacing percentage of 25%,30%,35%,100%. For each concrete mix, nine cubes (150mm X 150mm X 150mm) will be casted. For this above replacement percentage M25 mix will be prepared. The main objective of this project is to know the compressive strength of partial replaced concrete. To evaluate the strength, compressive strength test will be conducted. Also expecting result showing that the compressive strength of concrete is generally improved when it is compared with the conventional mix, with the increase of copper slag up to a certain percentage beyond which the strength reduces.

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{165097,
        author = {Chandan C S and MALLESH KUMAR K B and NAVYASHREE G and VIVEK G and YASHAS T R},
        title = {PARTIAL REPLACEMENT OF FINE AGGREGATE BY COPPER SLAG},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {11},
        number = {1},
        pages = {491-494},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=165097},
        abstract = {This project presents the usage of Copper Slag for the partial replacement of Fine aggregate the   experimental procedure will be conducted for the replacing percentage of 25%,30%,35%,100%. For each concrete mix, nine cubes (150mm X 150mm X 150mm) will be casted. For this above replacement percentage M25 mix will be prepared. The main objective of this project is to know the compressive strength of partial replaced concrete. To evaluate the strength, compressive strength test will be conducted. Also expecting result showing that the compressive strength of concrete is generally improved when it is compared with the conventional mix, with the increase of copper slag up to a certain percentage beyond which the strength reduces.},
        keywords = {Copper Slag, Fine Aggregate, Concrete, Strength, Workability, Density},
        month = {},
        }

Cite This Article

  • ISSN: 2349-6002
  • Volume: 11
  • Issue: 1
  • PageNo: 491-494

PARTIAL REPLACEMENT OF FINE AGGREGATE BY COPPER SLAG