Speech Pressure Monitoring Device for Parkinson's Disease

  • Unique Paper ID: 166106
  • Volume: 11
  • Issue: 2
  • PageNo: 349-352
  • Abstract:
  • Measurement of dynamic tongue and lip pressure is very important as this helps to understand the physiological deviations realistically and helps in quantifying some of the attributes of such deviations such as speech intelligibility issues secondary to neurological causes (e.g., Parkinson’s Disease). The skin attachable sensor is the component that is being developed in this work. The system will help the Parkinson Disease patient to get their speech pressure results without going to the laboratory. Here, the condenser microphone is used as the sensor which senses the sound waves falling on the diaphragm. The system is capable of measuring the speech pressure of the patient and assessing the severity level of the disease by comparing the speech pressure values with normal ones.

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{166106,
        author = {Rohan Pinto and Jennifer C. Saldanha and Roopashree and Deepthi S R},
        title = {Speech Pressure Monitoring Device for Parkinson's Disease},
        journal = {International Journal of Innovative Research in Technology},
        year = {2024},
        volume = {11},
        number = {2},
        pages = {349-352},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=166106},
        abstract = {Measurement of dynamic tongue and lip pressure is very important as this helps to understand the physiological deviations realistically and helps in quantifying some of the attributes of such deviations such as speech intelligibility issues secondary to neurological causes (e.g., Parkinson’s Disease). The skin attachable sensor is the component that is being developed in this work. The system will help the Parkinson Disease patient to get their speech pressure results without going to the laboratory. Here, the condenser microphone is used as the sensor which senses the sound waves falling on the diaphragm. The system is capable of measuring the speech pressure of the patient and assessing the severity level of the disease by comparing the speech pressure values with normal ones.},
        keywords = {Parkinson’s Disease, Sound Pressure Level, Healthy Controls},