  • Abstract:
  • In the proposed work, MATLAB Simulation of 1-phase to 3-phase Power electronic transformer (Solid state Transformer) is presented using MATLAB Simulink. The principal of operation of SST is described in detail. Firstly, the general performance of 1-phase to 3-phase Solid State transformer is presented using Resistive load and RL Load. The effect of Three-phase dead short circuit fault at the output terminal of SST will then be analyzed using MATLAB Simulink. Focus is given on the effect of input and output current due to short circuit fault at the output terminal of SST under different load condition is presented.

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{170141,
        author = {MANALI SHARMA and Monika Jain and C. S. Sharma and Deepti Jain},
        title = {Effect of Three-Phase Fault in the Single-phase to Three-phase Solid State Transformer using MATLAB Simulink},
        journal = {International Journal of Innovative Research in Technology},
        year = {2024},
        volume = {11},
        number = {6},
        pages = {3725-3731},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=170141},
        abstract = {In the proposed work, MATLAB Simulation of 1-phase to 3-phase Power electronic transformer (Solid state Transformer) is presented using MATLAB Simulink. The principal of operation of SST is described in detail. Firstly, the general performance of 1-phase to 3-phase Solid State transformer is presented using Resistive load and RL Load. The effect of Three-phase dead short circuit fault at the output terminal of SST will then be analyzed using MATLAB Simulink. Focus is given on the effect of input and output current due to short circuit fault at the output terminal of SST under different load condition is presented.},
        keywords = {SST, Solid-State Transformer, IGBT, Inverter, SPWM},
        month = {December},
        }

Cite This Article

  • ISSN: 2349-6002
  • Volume: 11
  • Issue: 6
  • PageNo: 3725-3731

Effect of Three-Phase Fault in the Single-phase to Three-phase Solid State Transformer using MATLAB Simulink

Related Articles