Performance Analysis of different Line filters for Single Phase Grid Connected Photovoltaic System in Secondary Distribution Network

  • Unique Paper ID: 189368
  • Volume: 12
  • Issue: 7
  • PageNo: 5642-5645
  • Abstract:
  • Grid-tied distributed generation systems (DG) are becoming more and more necessary to meet customer demands. In a low voltage distribution network, line filters are crucial for connecting solar photovoltaic (PV) installations to the utility grid. The IEEE1547 standard states that power injection from the inverter system to the utility grid shall have a unity power factor and few harmonics. In order to link single phase solar PV inverter systems in the low voltage (LV) distribution network, several line filters are provided. For example, these filters are used to remove harmonics from the inverter output waveform. This research estimates the Total Harmonic Distortion (THD) of the injected current by the PV inverters in the suggested system with various kinds of line filters and analyses the power factor in these scenarios. MATLAB/SIMULINK has been used to implement the system.

Copyright & License

Copyright © 2026 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{189368,
        author = {NEENU THOMAS},
        title = {Performance Analysis of different Line filters for Single Phase Grid Connected Photovoltaic System in Secondary Distribution Network},
        journal = {International Journal of Innovative Research in Technology},
        year = {2025},
        volume = {12},
        number = {7},
        pages = {5642-5645},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=189368},
        abstract = {Grid-tied distributed generation systems (DG) are becoming more and more necessary to meet customer demands. In a low voltage distribution network, line filters are crucial for connecting solar photovoltaic (PV) installations to the utility grid. The IEEE1547 standard states that power injection from the inverter system to the utility grid shall have a unity power factor and few harmonics. In order to link single phase solar PV inverter systems in the low voltage (LV) distribution network, several line filters are provided. For example, these filters are used to remove harmonics from the inverter output waveform. This research estimates the Total Harmonic Distortion (THD) of the injected current by the PV inverters in the suggested system with various kinds of line filters and analyses the power factor in these scenarios. MATLAB/SIMULINK has been used to implement the system.},
        keywords = {Distributed generation, Single phase solar PV systems, Line filter, Harmonics, THD, Power factor, Low voltage Distribution network MATLAB/SIMULINK.},
        month = {December},
        }

Cite This Article

THOMAS, N. (2025). Performance Analysis of different Line filters for Single Phase Grid Connected Photovoltaic System in Secondary Distribution Network. International Journal of Innovative Research in Technology (IJIRT), 12(7), 5642–5645.

Related Articles