Reactive Power Compensation Using FACTS Devices for Voltage Stability Improvement in Power Systems

  • Unique Paper ID: 210187
  • Volume: 13
  • Issue: 6
  • PageNo: 687-693
  • Abstract:
  • Reactive power compensation is important for maintaining acceptable voltage profiles and improving the operating performance of electrical power systems under varying loading conditions. This paper evaluates a simplified, bounded reactive-power injection model representing Static Synchronous Compensator (STATCOM) support in the IEEE-30 bus test system. Two equivalent compensators are considered at buses 26 and 30, with a reference voltage of 1.00 p.u. and an assumed reactive-power injection limit of ±10 MVAr per device. The system is evaluated at loading levels from 80% to 150% of the base load using Newton–Raphson power-flow analysis. The uncompensated and compensated cases are compared in terms of minimum bus voltage, voltage magnitudes at the controlled buses, active and reactive power losses, reactive-power injection, voltage-regulation error, convergence, and operating-limit status. At 100% loading, minimum voltage increases from 0.98256 p.u. to 0.99307 p.u. At 150% loading, it increases from 0.70724 p.u. to 0.84967 p.u.; active power losses decrease from 63.370 MW to 54.928 MW, and reactive power losses decrease from approximately 219.15 MVAr to 182.48 MVAr. However, the assumed reactive-power limits are reached under high loading, and voltage references cannot always be maintained. The results show the potential benefits and capacity limitations of the implemented simplified model and should not be interpreted as validation of a detailed converter-based STATCOM.

Copyright & License

Copyright © 2026 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{210187,
        author = {Aswar Kamlesh and Mrs. Rachana Patel},
        title = {Reactive Power Compensation Using FACTS Devices for Voltage Stability Improvement in Power Systems},
        journal = {International Journal of Innovative Research in Technology},
        year = {2026},
        volume = {13},
        number = {6},
        pages = {687-693},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=210187},
        abstract = {Reactive power compensation is important for maintaining acceptable voltage profiles and improving the operating performance of electrical power systems under varying loading conditions. This paper evaluates a simplified, bounded reactive-power injection model representing Static Synchronous Compensator (STATCOM) support in the IEEE-30 bus test system. Two equivalent compensators are considered at buses 26 and 30, with a reference voltage of 1.00 p.u. and an assumed reactive-power injection limit of ±10 MVAr per device. The system is evaluated at loading levels from 80% to 150% of the base load using Newton–Raphson power-flow analysis. The uncompensated and compensated cases are compared in terms of minimum bus voltage, voltage magnitudes at the controlled buses, active and reactive power losses, reactive-power injection, voltage-regulation error, convergence, and operating-limit status. At 100% loading, minimum voltage increases from 0.98256 p.u. to 0.99307 p.u. At 150% loading, it increases from 0.70724 p.u. to 0.84967 p.u.; active power losses decrease from 63.370 MW to 54.928 MW, and reactive power losses decrease from approximately 219.15 MVAr to 182.48 MVAr. However, the assumed reactive-power limits are reached under high loading, and voltage references cannot always be maintained. The results show the potential benefits and capacity limitations of the implemented simplified model and should not be interpreted as validation of a detailed converter-based STATCOM.},
        keywords = {Reactive power compensation, FACTS devices, STATCOM, IEEE-30 bus system, voltage profile, power losses, loading variation.},
        month = {November},
        }

Cite This Article

Kamlesh, A., & Patel, M. R. (2026). Reactive Power Compensation Using FACTS Devices for Voltage Stability Improvement in Power Systems. International Journal of Innovative Research in Technology (IJIRT), 13(6), 687–693.

Related Articles