Comparison of Cascade Control Technique for High Temperature Short Time Pasteurization System

  • Unique Paper ID: 147219
  • Volume: 5
  • Issue: 6
  • PageNo: 63-68
  • Abstract:
  • In this study control systems such as cascade, single loop and multivariable systems are compared for control of High Temperature Short Time Pasteurization are compared against each other using computer system. Here it is seen that how system cascade provides a much smoother temperature response curve compared to single loop systems even though they show a slower recovery. But this paper also shows how multivariable approach is able to recover faster and also show a much smoother temperature response curve. The temperature data recorded by the data acquisition system has recorded the data within an error limit of ±0.1℃ and thus the data acquisition system is a much complete way of measuring and recording the temperature data for this study.

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{147219,
        author = {V. RAM KUMAR},
        title = {Comparison of Cascade Control Technique for High Temperature Short Time Pasteurization System},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {5},
        number = {6},
        pages = {63-68},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=147219},
        abstract = {In this study control systems such as cascade, single loop and multivariable systems are compared for control of High Temperature Short Time Pasteurization are compared against each other using computer system. Here it is seen that how system cascade provides a much smoother temperature response curve compared to single loop systems even though they show a slower recovery. But this paper also shows how multivariable approach is able to recover faster and also show a much smoother temperature response curve. The temperature data recorded by the data acquisition system has recorded the data within an error limit of ±0.1℃ and thus the data acquisition system is a much complete way of measuring and recording the temperature data for this study. },
        keywords = {data acquisition; dairy; pasteurization; high temperature, short-time controls)
Abbreviation key: DAS = data acquisition system; FDV = flow diversion valve; LTC = LABTECH Control; PMO = Grade-A Pasteurized Milk Ordinance, 1993 Revision; STLR = safety thermal limit recorder.
},