Time History Analysis Of Structure Subjected To Biaxial Excitation
Author(s):
NILESH S PATIL, ANIKET RENAVIKAR, SNEHAL R PATIL
Keywords:
Biaxial Excitation, Stiffness, Uniform Distribution, Seismic Response
Abstract
Major structural collapses occur when a building is under the action of dynamic loadswhich includes both earthquake and wind loads. In these modern days, most of thestructures are involved with architectural attributes and it is highly impossible to plan with irregular shapes. These irregularities areresponsible for structural collapse of buildings under the action of dynamic loads. Hence, extensive research is required for achieving ultimate performance even with a poor configuration. A building is said to be a regular when it is symmetric about the axis and it is said to be the irregular when it lacks symmetry and discontinuity in geometry, mass or load resisting elements. During an earthquake, failure of structure starts at points of weakness. This weakness arises due to discontinuity in mass, stiffness and geometry of structure. The structures having this discontinuity are termed as Irregular structures. Irregular structures contribute a large portion of urban infrastructure.Earthquakes are one of the most devastating natural hazards that cause great loss of life and livelihood. Most recent earthquakes have shown that the irregular distribution of mass, stiffness and strengths may cause serious damage in structural systems, such buildings undergo torsional motions. An ideal multistory building designed to resist lateral loads due to earthquake would consist of only symmetric distribution of mass and stiffness in plan at every storey and a uniform distribution along height of the building. Such a building would respond only laterally and is considered as torsionally balanced (TB) building. But it is very difficult to achieve such a condition because of restrictions such as architectural requirement and functional needs. The structures whose performances were evaluated in this study, are designed with the provisions from IS: 1893-2002. Equivalent static force method of determining earthquake force is limited to the structures having height of less than 40 meters. Hence this study deals with medium rise buildings (ten storied). The purpose of proposed work is to investigate the seismic response of structure with realistic approach with an analysis method of time history analysis.
Article Details
Unique Paper ID: 145008

Publication Volume & Issue: Volume 4, Issue 6

Page(s): 406 - 408
Article Preview & Download


Share This Article

Join our RMS

Conference Alert

NCSEM 2024

National Conference on Sustainable Engineering and Management - 2024

Last Date: 15th March 2024

Call For Paper

Volume 10 Issue 10

Last Date for paper submitting for March Issue is 25 June 2024

About Us

IJIRT.org enables door in research by providing high quality research articles in open access market.

Send us any query related to your research on editor@ijirt.org

Social Media

Google Verified Reviews