ANALYTICAL STUDY ON STOREY DISPLACEMENT AND DRIFT RATIO OF H SHAPE AND STEP BACK SET BACK MULTISTORIED BUILDINGS ON SLOPING GROUND
Author(s):
RITESH SARVADE
Keywords:
Multistorey building, Hill Slope angle, Step back set back structure, H shape structure, Shear wall, Time history analysis.
Abstract
Framed structures constructed on hill slopes shows different structural behavior than that on the plain ground. Since these buildings are unsymmetrical in nature, hence shows unequal distribution due to varying column height and length. In the present study, the multi storied building is considered for the study. The seismic analysis of different structural configuration such as step back set back structure and H shape structure is considered. Based on different structural configurations, the responses have been studied and analyzed by using latest application software. The study is carried by using time history method. The past three severe earthquakes occurred in India are studied. It is observed that the Step back set back structure performs better as compared to H shape structure for without shear wall. It is also observed that the H shape structure with internal as well as external shear wall performed better as compared to Step back set back structure.
Article Details
Unique Paper ID: 154309
Publication Volume & Issue: Volume 8, Issue 10
Page(s): 496 - 501
Article Preview & Download
Share This Article
Conference Alert
NCSST-2023
AICTE Sponsored National Conference on Smart Systems and Technologies
Last Date: 25th November 2023
SWEC- Management
LATEST INNOVATION’S AND FUTURE TRENDS IN MANAGEMENT