  • Abstract:
  • A viscometer is an instrument used to measure the viscosity and flow parameters of a liquid. Viscosity of a liquid is directly proportional to the flow time through a capillary tube. In glass capillary viscometer the time required for the liquid level to drop from one mark to another is generally measured by a stop watch. As the liquid flows quickly through the glass tube, accurate measurement of time by a stop watch is very difficult. To solve this problem a digital watch is constructed which automatically start at upper mark and stop at lower mark of the viscometer. This apparatus works for electro conductive liquid and gives good results. 2-input EX-OR gate is used for automatic start and stop operations of this digital watch. A new electronic method is used here to measure time of rise or time of fall of liquid level automatically.

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{155002,
        author = {DILIP PAUL},
        title = {DIGITAL MEASUREMENT OF FLOW TIME FOR ELECTRO-CONDUCTIVE LIQUID IN A GLASS CAPILLARY VISCOMETER},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {8},
        number = {12},
        pages = {1034-1038},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=155002},
        abstract = {A viscometer is an instrument used to measure the viscosity and flow parameters of a liquid. Viscosity of a liquid is directly proportional to the flow time through a capillary tube.  In glass capillary viscometer the time required for the liquid level to drop from one mark to another is generally measured by a stop watch. As the liquid flows quickly through the glass tube, accurate measurement of time by a stop watch is very difficult. To solve this problem a digital watch is constructed which automatically start at upper mark and stop at lower mark of the viscometer. This apparatus works for electro conductive liquid and gives good results. 2-input EX-OR gate is used for automatic start and stop operations of this digital watch. A new electronic method is used here to measure time of rise or time of fall of liquid level automatically.},