HARMONICS ELIMINATION IN POWER GENERATION USING ACTIVE POWER FILTER

  • Unique Paper ID: 149596
  • Volume: 7
  • Issue: 1
  • PageNo: 40-45
  • Abstract:
  • In distribution systems, the load has been a sudden increase or decreases and it is like as nonlinear loads so the load draw non-sinusoidal currents from the AC mains and causes the load harmonics and reactive power, and excessive neutral currents that give pollution in power systems. Most pollution problems created in power systems are due to the nonlinear characteristics and fast switching of power electronic devices. Shunt active filter based on current controlled PWM converters are seen as a most viable solution. This paper presents the harmonics and reactive power compensation from 3P4W micro-grid distribution system by IP controlled shunt active. The technique which is used for generate desired compensation current extraction based on offset command instantaneous currents distorted or voltage signals in the time domain because compensation time domain response is quick, easy implementation and lower computational load compared to the frequency domain

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{149596,
        author = {SRINIVASA ACHARYA and A. Srihari and A. Bharadwaj manikanta and T. Sai gowtham and C. Jagadeesh and K. Tanuj},
        title = {HARMONICS ELIMINATION IN POWER GENERATION USING ACTIVE POWER FILTER},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {7},
        number = {1},
        pages = {40-45},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=149596},
        abstract = {In distribution systems, the load has been a sudden increase or decreases and it is like as nonlinear loads so the load draw non-sinusoidal currents from the AC mains and causes the load harmonics and reactive power, and excessive neutral currents that give pollution in power systems. Most pollution problems created in power systems are due to the nonlinear characteristics and fast switching of power electronic devices. Shunt active filter based on current controlled PWM converters are seen as a most viable solution. This paper presents the harmonics and reactive power compensation from 3P4W micro-grid distribution system by IP controlled shunt active. The technique which is used for generate desired compensation current extraction based on offset command instantaneous currents distorted or voltage signals in the time domain because compensation time domain response is quick, easy implementation and lower computational load compared to the frequency domain},
        keywords = {micro grid, level inverters, renewable energy sources},