Microcontroller Based detection and protection of induction motor

  • Unique Paper ID: 151252
  • Volume: 7
  • Issue: 12
  • PageNo: 252-255
  • Abstract:
  • The fundamental aim of this project is to trip the relay if the faultis occurring in three phase induction motor. A low cost and reliable protection scheme has been designed which monitors the parameter of induction motor such as current, temperature and speed of motor. Circuit measures this parameter by CT, Tachometer, Temperature sensor and then the collected data will feed to the microcontroller. LCD will display the measured value if the measured value will cross the specified limited then GSM will send the measured value to the registered mobile number and relay will operate and supply is to be cut off and motor will stop. This type of protection takes fraction of second

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{151252,
        author = {Sudhanshu pathak and Shripad G Desai },
        title = {Microcontroller Based detection and protection of induction motor  },
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {7},
        number = {12},
        pages = {252-255},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=151252},
        abstract = {The fundamental aim of this project is to trip the relay if the faultis occurring in three phase induction motor. A low cost and reliable protection scheme has been designed which monitors the parameter of induction motor such as current, temperature and speed of motor. Circuit measures this parameter by CT, Tachometer, Temperature sensor and then the collected data will feed to the microcontroller. LCD will display the measured value if the measured value will cross the specified limited then GSM will send the measured value to the registered mobile number and relay will operate and supply is to be cut off and motor will stop. This type of protection takes fraction of second},
        keywords = {},
        month = {},
        }

Cite This Article

  • ISSN: 2349-6002
  • Volume: 7
  • Issue: 12
  • PageNo: 252-255

Microcontroller Based detection and protection of induction motor

Related Articles