TYPE IIIA COMPOUND TIBIA FRACTURES TREATED WITH A LOCKING PLATE AS AN EXTERNAL FIXATOR

  • Unique Paper ID: 209522
  • Volume: 13
  • Issue: 5
  • PageNo: 2571-2575
  • Abstract:
  • Background: Most of lower leg external fixation are bulky and cumbersome and provides only temporary bony stabilization. Anatomically pre-contoured supracutaneous LCP has been utilized by many authors as an external fixator in patients with metaphyseal and diaphyseal fractures of tibia. Aim: The aim of this study is to analyse the end result of Supracutaneous LCP as a definitive external fixation and its effect on rate of union in metaphyseal and diaphyseal fractures. Materials and methods: A complete of 30 patients of compound fractures of tibia underwent “supracutaneous plating” of the tibia using an LCP. Average age was 44 years. Regular screw tract dressings were done. Average period of follow-up was 13 months. Results: The plate was kept ex situ for a period of 24-30 weeks. Proximal metaphysis, diaphysis and distal metaphysis united in 14 weeks, 20 weeks and 16 weeks respectively. Total of 30 patients were operated for Supracutaneous LCP of which one complicated with Infected Non-union resulting in implant removal and other complicated with non-union which later underwent internal fixation. Conclusion: In compound fractures of tibia supracutaneous LCP are often used as a definitive external fixator because it gives good results especially for metaphyseal fractures and fewer complication rates, with Adequate stability. Advantageous effect of LCP in facilitating wound healing, cosmetic surgery procedure. Because it does not strike the contralateral leg therefore cosmetically acceptable and functional while ambulation. Because of nonoverlapping of implants fracture healing is easily assessed on x rays.

Copyright & License

Copyright © 2026 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{209522,
        author = {Dr.Mayur Vikas Jagtap},
        title = {TYPE IIIA COMPOUND TIBIA FRACTURES TREATED WITH A LOCKING PLATE AS AN EXTERNAL FIXATOR},
        journal = {International Journal of Innovative Research in Technology},
        year = {2026},
        volume = {13},
        number = {5},
        pages = {2571-2575},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=209522},
        abstract = {Background: Most of lower leg external fixation are bulky and cumbersome and provides only temporary bony stabilization. Anatomically pre-contoured supracutaneous LCP has been utilized by many authors as an external fixator in patients with metaphyseal and diaphyseal fractures of tibia.

Aim: The aim of this study is to analyse the end result of Supracutaneous LCP as a definitive external fixation and its effect on rate of union in metaphyseal and diaphyseal fractures.

Materials and methods: A complete of 30 patients of compound fractures of tibia underwent “supracutaneous plating” of the tibia using an LCP. Average age was 44 years. Regular screw tract dressings were done. Average period of follow-up was 13 months. 

Results: The plate was kept ex situ for a period of 24-30 weeks. Proximal metaphysis, diaphysis and distal metaphysis united in 14 weeks, 20 weeks and 16 weeks respectively. Total of 30 patients were operated for Supracutaneous LCP of which one complicated with Infected Non-union resulting in implant removal and other complicated with non-union which later underwent internal fixation. 

Conclusion: In compound fractures of tibia supracutaneous LCP are often used as a definitive external fixator because it gives good results especially for metaphyseal fractures and fewer complication rates, with Adequate stability. Advantageous effect of LCP in facilitating wound healing, cosmetic surgery procedure. Because it does not strike the contralateral leg therefore cosmetically acceptable and functional while ambulation. Because of nonoverlapping of implants fracture healing is easily assessed on x rays.},
        keywords = {Supracutaneous LCP, Compound Tibial Fractures, External Fixation by Plate, Locking Compression Plate},
        month = {October},
        }

Cite This Article

Jagtap, D. V. (2026). TYPE IIIA COMPOUND TIBIA FRACTURES TREATED WITH A LOCKING PLATE AS AN EXTERNAL FIXATOR. International Journal of Innovative Research in Technology (IJIRT), 13(5), 2571–2575.

Related Articles