Seismic Behaviour of High-Rise Buildings with Steel- Concrete Composite Shear Walls

  • Unique Paper ID: 211093
  • Volume: 13
  • Issue: 6
  • PageNo: 4006-4019
  • Abstract:
  • The increasing construction of high-rise buildings in earthquake prone regions has created a need for efficient structural systems capable of resisting significant lateral forces. Shear walls are widely adopted to improve the lateral stiffness, strength, and stability of buildings subjected to seismic loading. However, conventional Reinforced Cement Concrete (RCC) and steel plate shear walls have certain limitations, including concrete cracking, reinforcement congestion, and steel plate buckling. Steel–concrete composite shear walls have emerged as an effective alternative by combining the compressive strength of concrete with the tensile strength and ductility of steel. The present study investigates the seismic behaviour of high-rise buildings incorporating different configurations of composite shear walls using ETABS. The analytical investigation considers buildings of 20, 25, and 30 storeys and examines four composite shear wall configurations: Double Skin Composite Shear Wall (DS-CSW), Steel Encased Composite Shear Wall (SE-CSW), Steel Encased with I-Section Composite Shear Wall (SEI-CSW), and Composite Shear Wall with I-Section (I-Section CSW). Two wall thicknesses, 200 mm and 300 mm, are considered for comparison with conventional RCC shear walls. Response spectrum analysis is adopted in accordance with Indian seismic design provisions. The structural response is evaluated in terms of storey displacement, inter-storey drift, storey shear, and lateral stiffness. The study aims to identify an efficient composite shear wall configuration that provides improved seismic performance, deformation control, and structural efficiency. The findings are intended to contribute to the application of steel–concrete composite shear walls in earthquake-resistant high-rise building design.

Copyright & License

Copyright © 2026 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{211093,
        author = {Jayshree Beldar and S. R. Takkalaki},
        title = {Seismic Behaviour of High-Rise Buildings with Steel- Concrete Composite Shear Walls},
        journal = {International Journal of Innovative Research in Technology},
        year = {2026},
        volume = {13},
        number = {6},
        pages = {4006-4019},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=211093},
        abstract = {The increasing construction of high-rise buildings in earthquake prone regions has created a need for efficient structural systems capable of resisting significant lateral forces. Shear walls are widely adopted to improve the lateral stiffness, strength, and stability of buildings subjected to seismic loading. However, conventional Reinforced Cement Concrete (RCC) and steel plate shear walls have certain limitations, including concrete cracking, reinforcement congestion, and steel plate buckling. Steel–concrete composite shear walls have emerged as an effective alternative by combining the compressive strength of concrete with the tensile strength and ductility of steel. The present study investigates the seismic behaviour of high-rise buildings incorporating different configurations of composite shear walls using ETABS. The analytical investigation considers buildings of 20, 25, and 30 storeys and examines four composite shear wall configurations: Double Skin Composite Shear Wall (DS-CSW), Steel Encased Composite Shear Wall (SE-CSW), Steel Encased with I-Section Composite Shear Wall (SEI-CSW), and Composite Shear Wall with I-Section (I-Section CSW). Two wall thicknesses, 200 mm and 300 mm, are considered for comparison with conventional RCC shear walls. Response spectrum analysis is adopted in accordance with Indian seismic design provisions. The structural response is evaluated in terms of storey displacement, inter-storey drift, storey shear, and lateral stiffness. The study aims to identify an efficient composite shear wall configuration that provides improved seismic performance, deformation control, and structural efficiency. The findings are intended to contribute to the application of steel–concrete composite shear walls in earthquake-resistant high-rise building design.},
        keywords = {Steel concrete composite shear walls, seismic behaviour, high rise buildings, response spectrum analysis, storey displacement, storey drift, lateral stiffness, RCC shear walls.},
        month = {November},
        }

Cite This Article

Beldar, J., & Takkalaki, S. R. (2026). Seismic Behaviour of High-Rise Buildings with Steel- Concrete Composite Shear Walls. International Journal of Innovative Research in Technology (IJIRT), 13(6), 4006–4019.

Related Articles