Behavior of the Reinforced concrete column with recycled coarse aggregate and natural coarse aggregate

  • Unique Paper ID: 143891
  • Volume: 3
  • Issue: 3
  • PageNo: 83-92
  • Abstract:
  • The experimental study involve the reinforced concrete columns with recycled concrete coarse aggregate. The experiment will be between the normal strength concrete columns of 150x150x400mm specimens (with different RCA amounts) are presented and compared with predictions from code-based procedures for conventional concrete Work involved in the project are material collection from different sources. Base on sample of source material testing, Mix design, Test on fresh concrete, Workability testing, slump testing , Testing of harden concrete cubes, Compression testing ,Flexural testing, Split tensile testing, Casting of columns, Experimental testing. Short column were tested in compression testing machine and following ultimate failure loads ,strain in following load and cracks in column.
add_icon3email to a friend

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{143891,
        author = {Abhay Mathews and Gopika Moorthy},
        title = {Behavior of the Reinforced concrete column with recycled coarse aggregate and natural coarse aggregate},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {3},
        number = {3},
        pages = {83-92},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=143891},
        abstract = {The experimental study involve the reinforced concrete columns with recycled concrete coarse aggregate. The experiment will be between the normal strength concrete columns of 150x150x400mm specimens (with different RCA amounts) are presented and compared with predictions from  code-based procedures for conventional concrete Work  involved in the project are material collection from different sources. Base on   sample of source material testing, Mix design, Test on fresh concrete, Workability testing, slump testing , Testing of harden concrete cubes, Compression testing ,Flexural testing, Split tensile testing, Casting of columns, Experimental testing. Short column were tested in compression testing machine and following ultimate failure loads ,strain in following load and cracks in column.},
        keywords = {Recycled coarse aggregate (RCA), natural coarse aggregate (NCA), compression testing machine (CTM), ordinary Portland cement (OPC).},