EFFECT OF CONSTRUCTION SEQUENCE ANALYSIS ON RC BUILDING STRUCTURE

  • Unique Paper ID: 156247
  • Volume: 9
  • Issue: 3
  • PageNo: 204-207
  • Abstract:
  • Rising incidents of failure of buildings during the construction phase is an increasing concern in India. The failure of structural elements like slabs, beams, columns, and shear walls is critical. Construction sequence analysis (CSA) helps in analyzing the building in a staged fashion. This study analyzed the values of structural parameters of a 10 storied building is measured these results against the dynamic analysis of the building. The values of deflection and shear forces found in CSA are up to 35% more than dynamic analysis. This study definitively answers the question regarding the failure of buildings during the construction phase and how it can be avoided by using CSA. This study definitively answers the question regarding the failure of buildings during the construction phase and how it can be avoided by using CSA.

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{156247,
        author = {Basavashree Kaji and Gajendra.H},
        title = {EFFECT OF CONSTRUCTION SEQUENCE ANALYSIS ON RC BUILDING STRUCTURE},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {9},
        number = {3},
        pages = {204-207},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=156247},
        abstract = {Rising incidents of failure of buildings during the construction phase is an increasing concern in India. The failure of structural elements like slabs, beams, columns, and shear walls is critical. Construction sequence analysis (CSA) helps in analyzing the building in a staged fashion. This study analyzed the values of structural parameters of a 10 storied building is measured these results against the dynamic analysis of the building. The values of deflection and shear forces found in CSA are up to 35% more than dynamic analysis. This study definitively answers the question regarding the failure of buildings during the construction phase and how it can be avoided by using CSA. This study definitively answers the question regarding the failure of buildings during the construction phase and how it can be avoided by using CSA.},
        keywords = {Construction sequence analysis, conventional method, E-tabs software},
        month = {},
        }

Cite This Article