An False Data Injection Detection using Sensor based Control Protocol in Different Cases of Cyber Physical System.

  • Unique Paper ID: 181619
  • PageNo: 5099-5104
  • Abstract:
  • Safeguarding cyber-physical systems (CPSs) from cyberattacks is becoming ever more essential. False data injection assaults, which alter sensor readings and control signals, are one of the many dangers that could seriously impair CPS operation. This research presents a strong security strategy based on the idea of energy conversion to counter measured bogus data injection attacks. After that, an energy controller is created to dynamically control system energy in reaction to unidentified threats. The controller keeps the system stable and its dynamic performance intact by varying damping injection. Furthermore, the design of control systems is made simpler by the use of a disturbance attenuation technique, which removes the requirement to create an attack observer. By avoiding intricate mathematical processes, the suggested approach is also useful. An industrial CPS that manages a permanent magnet synchronous motor is used to verify its efficacy.

Copyright & License

Copyright © 2026 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{181619,
        author = {A.Joshua Issac and Dr. S.Shanmuga Priya},
        title = {An False Data Injection Detection using Sensor based Control Protocol in Different Cases of Cyber Physical System.},
        journal = {International Journal of Innovative Research in Technology},
        year = {2025},
        volume = {12},
        number = {1},
        pages = {5099-5104},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=181619},
        abstract = {Safeguarding cyber-physical systems (CPSs) from cyberattacks is becoming ever more essential. False data injection assaults, which alter sensor readings and control signals, are one of the many dangers that could seriously impair CPS operation. This research presents a strong security strategy based on the idea of energy conversion to counter measured bogus data injection attacks. After that, an energy controller is created to dynamically control system energy in reaction to unidentified threats. The controller keeps the system stable and its dynamic performance intact by varying damping injection. Furthermore, the design of control systems is made simpler by the use of a disturbance attenuation technique, which removes the requirement to create an attack observer. By avoiding intricate mathematical processes, the suggested approach is also useful. An industrial CPS that manages a permanent magnet synchronous motor is used to verify its efficacy.},
        keywords = {},
        month = {June},
        }

Cite This Article

Issac, A., & Priya, D. S. (2025). An False Data Injection Detection using Sensor based Control Protocol in Different Cases of Cyber Physical System.. International Journal of Innovative Research in Technology (IJIRT), 12(1), 5099–5104.

Related Articles