Implementation in Automatic Star Delta Starter with Protection Scheme

  • Unique Paper ID: 143398
  • Volume: 2
  • Issue: 11
  • PageNo: 254-257
  • Abstract:
  • The project is designed to provide low voltage start to induction motor. This is achieved by using star to delta conversion. The star delta starter is generally obtained from three contractors, electromechanical timer and a thermal overload for operating a 3 phase motor at 440 volt at ac mains supply 50Hz.A set of relays are used to shift the motor connections from star to delta with a time delay. Since in star connection current is same in different phases while line voltage is root three times the phase voltage. So the voltage is reduced if motor is started as star. And also in delta connection the voltage is same as that of phase voltage so full voltage is applied if we run the motor as delta connection. The interlocking arrangement of all the contactor coils is traditionally wired in 440volt AC. If any of the phase goes off the single phasing circuit comes into action which disconnect the motor and save it from overloading.

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{143398,
        author = {Mrunal Kolhe and Ranjan Kumar and Suraj Dhanvijay and C. J. Sharma},
        title = {Implementation in Automatic Star Delta Starter with Protection Scheme},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {2},
        number = {11},
        pages = {254-257},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=143398},
        abstract = {The project is designed to provide low voltage start to induction motor. This is achieved by using star to delta conversion. The star delta starter is generally obtained from three contractors, electromechanical timer and a thermal overload for operating a 3 phase motor at 440 volt at ac mains supply 50Hz.A set of relays are used to shift the motor connections from star to delta with a time delay. Since in star connection current is same in different phases while line voltage is root three times the phase voltage. So the voltage is reduced if motor is started as star. And also in delta connection the voltage is same as that of phase voltage so full voltage is applied if we run the motor as delta connection. The interlocking arrangement of all the contactor coils is traditionally wired in 440volt AC. If any of the phase goes off the single phasing circuit comes into action which disconnect the motor and save it from overloading.},
        keywords = {Commutator,plugging,auxillary,stater,rectifier,torque.},
        month = {},
        }

Cite This Article

  • ISSN: 2349-6002
  • Volume: 2
  • Issue: 11
  • PageNo: 254-257

Implementation in Automatic Star Delta Starter with Protection Scheme

Related Articles