EXPERIMENTAL ANALYSIS OF DOMESTIC REFRIGERATOR USING AIRCOOLED AND EVAPORATIVE TYPE CONDENSERS

  • Unique Paper ID: 147029
  • Volume: 5
  • Issue: 3
  • PageNo: 123-127
  • Abstract:
  • The main aim of this article is to analyze the performance of refrigerator connected with air cooled as well as evaporative type condenser. As refrigerator uses the vapor compression cycle in its process. The performance of this system becomes the main problem and many investigations are still under way to evaluate and improve the efficiency of the system. This article presents the effect of the evaporative condenser in the COP of the domestic refrigerator. The purpose of this article is to compare the COP of the refrigerator using an air-cooled condenser and an evaporative condenser of the same length and diameter. This experiment is conducted in a domestic refrigerator (Godrej Classic) of 165 liters of capacity assembled with a test platform. In this study an innovative evaporative condenser for residential refrigerator was introduced. To allow evaporative cooling, the cotton was wrapped around the condenser to suck the water sprayed onto it. The thermal properties at different points in the refrigeration cycle were measured for typical operating conditions for both air cooled condenser and evaporative type condenser

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{147029,
        author = {Kostubh Namdeo},
        title = {EXPERIMENTAL ANALYSIS OF DOMESTIC REFRIGERATOR USING AIRCOOLED AND EVAPORATIVE TYPE CONDENSERS},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {5},
        number = {3},
        pages = {123-127},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=147029},
        abstract = {The main aim of this article is to analyze the performance of refrigerator connected with air cooled as well as evaporative type condenser. As refrigerator uses the vapor compression cycle in its process. The performance of this system becomes the main problem and many investigations are still under way to evaluate and improve the efficiency of the system. This article presents the effect of the evaporative condenser in the COP of the domestic refrigerator. The purpose of this article is to compare the COP of the refrigerator using an air-cooled condenser and an evaporative condenser of the same length and diameter. This experiment is conducted in a domestic refrigerator (Godrej Classic) of 165 liters of capacity assembled with a test platform. In this study an innovative evaporative condenser for residential refrigerator was introduced. To allow evaporative cooling, the cotton was wrapped around the condenser to suck the water sprayed onto it. The thermal properties at different points in the refrigeration cycle were measured for typical operating conditions for both air cooled condenser and evaporative type condenser},
        keywords = {Air cooled condenser, Evaporative cooling.},
        month = {},
        }

Cite This Article

  • ISSN: 2349-6002
  • Volume: 5
  • Issue: 3
  • PageNo: 123-127

EXPERIMENTAL ANALYSIS OF DOMESTIC REFRIGERATOR USING AIRCOOLED AND EVAPORATIVE TYPE CONDENSERS