ANALYSIS AND DESIGN OF MULTI-STOREY BUILDING G+6 BY USING STAADPRO

  • Unique Paper ID: 182783
  • Volume: 12
  • Issue: 2
  • PageNo: 3704-3714
  • Abstract:
  • Now a days tall or multi-storey buildings has gain very much importance, because in metro cities there is a rapid increase in population with limited land. All people require good ac- commodations, aesthetic, comfort and safety. Thats the reason for increase in construction of multi-storey buildings. Structural design of multi-storey buildings is basically worried with safety during ground motion, serviceability what’s more, potential for monetary misfortune. Design of structures using Limit State Method Design the members are designed for the limiting bending moment and serviceability limits, hence the structures are left with minimum reserve energy. Earthquake will cause more severe effect on tall buildings compare to small buildings. Due to earthquake asymmetrical buildings will damage more than symmetrical buildings. In case of high rise structures horizontal loads produce develop high lateral displacements which is not desirable for the occupants and the structure itself. The enormous increase in population and scarcity of land makes the people to move from rural areas to urban paces and construction of multi-storied buildings in small areas is being common now-a-days. Functional designing of the building has become very important and the requirements vary from one building to another. Every Civil Engineer should know the usage of the buildings by contacting the people and basic principles of designing of the R.C.C structures. This is project is intended at Analyzing and designing the multi-storey structure using STAAD. PRO V8i and STAAD. etc. In this project, we adopted limit state method of analysis and design the structural members using STAAD.PRO.V8i and STAAD. Etc. Design is done for particular beam, column and slab by using IS456:2000 and loads are dead load, imposed load and external load considered according to IS 875:1987 (PART III).It is then checked in STAAD.P RO.V8i and STAAD. Few standard problems also have been solved to show how STAAD. Pro can be used in different cases. These typical problems have been solved using basic concept of loading, analysis, condition as per IS code. These basic techniques may be found useful for further analysis of problems.

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{182783,
        author = {Airaj Ahmed Quraishi and Dr. Gugulothu Vikas and MOHAMMED JALAL UDDIN},
        title = {ANALYSIS AND DESIGN OF MULTI-STOREY BUILDING G+6 BY USING STAADPRO},
        journal = {International Journal of Innovative Research in Technology},
        year = {2025},
        volume = {12},
        number = {2},
        pages = {3704-3714},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=182783},
        abstract = {Now a days tall or multi-storey buildings has gain very much importance, because in metro cities there is a rapid increase in population with limited land. All people require good ac- commodations, aesthetic, comfort and safety. Thats the reason for increase in construction of multi-storey buildings.
Structural design of multi-storey buildings is basically worried with safety during ground motion, serviceability what’s more, potential for monetary misfortune. Design of structures using Limit State Method Design the members are designed for the limiting bending moment and serviceability limits, hence the structures are left with minimum reserve energy. Earthquake will cause more severe effect on tall buildings compare to small buildings. Due to earthquake asymmetrical buildings will damage more than symmetrical buildings. In case of high rise structures horizontal loads produce develop high lateral displacements which is not desirable for the occupants and the structure itself.
The enormous increase in population and scarcity of land makes the people to move from rural areas to urban paces and construction of multi-storied buildings in small areas is being common now-a-days. Functional designing of the building has become very important and the requirements vary from one building to another. Every Civil Engineer should know the usage of the buildings by contacting the people and basic principles of designing of the R.C.C structures. This is project is intended at Analyzing and designing the multi-storey structure using STAAD. PRO V8i and STAAD. etc. In this project, we adopted limit state method of analysis and design the structural members using STAAD.PRO.V8i and STAAD. Etc.  Design is done for particular beam, column and slab by using IS456:2000 and loads are dead load, imposed load and external load considered according to IS 875:1987 (PART III).It is then checked in STAAD.P RO.V8i and STAAD.
 Few standard problems also have been solved to show how STAAD. Pro can be used in different cases. These typical problems have been solved using basic concept of loading, analysis, condition as per IS code. These basic techniques may be found useful for further analysis of problems.},
        keywords = {StaadPro, multi-storey building, shear force, bending moment.},
        month = {July},
        }

Cite This Article

  • ISSN: 2349-6002
  • Volume: 12
  • Issue: 2
  • PageNo: 3704-3714

ANALYSIS AND DESIGN OF MULTI-STOREY BUILDING G+6 BY USING STAADPRO