An Efficient Control Strategy for Three-PhaseInverter in Distributed Generation

  • Unique Paper ID: 143105
  • PageNo: 491-497
  • Abstract:
  • The proposed control strategycomposes of an inner inductor current loop, and anovel voltage loop in the synchronous referenceframe. The inverter is regulated as a current sourcejust by the inner inductor current loop in grid-tiedoperation, and the voltage controller is automaticallyactivated to regulate the load voltage upon theoccurrence of islanding. Furthermore, the waveformof the grid current in the grid-tied mode and the loadvoltage in the islanding mode are distorted undernonlinear local load with the conventional strategy.And this issue is addressed by proposing a unifiedload current feed-forward in this paper. Finally, theeffectiveness of the proposed control strategy isvalidated by the simulation results.

Copyright & License

Copyright © 2026 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{143105,
        author = {K.Sree Ramudu and D.Masthan},
        title = {An Efficient Control Strategy for Three-PhaseInverter in Distributed Generation},
        journal = {International Journal of Innovative Research in Technology},
        year = {},
        volume = {2},
        number = {7},
        pages = {491-497},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=143105},
        abstract = {The proposed control strategycomposes of an inner inductor current loop, and anovel voltage loop in the synchronous referenceframe. The inverter is regulated as a current sourcejust by the inner inductor current loop in grid-tiedoperation, and the voltage controller is automaticallyactivated to regulate the load voltage upon theoccurrence of islanding. Furthermore, the waveformof the grid current in the grid-tied mode and the loadvoltage in the islanding mode are distorted undernonlinear local load with the conventional strategy.And this issue is addressed by proposing a unifiedload current feed-forward in this paper. Finally, theeffectiveness of the proposed control strategy isvalidated by the simulation results.},
        keywords = {Distributed generation (DG), Islanding, load current, seamless transfer, three-phaseinverter.},
        month = {},
        }

Cite This Article

Ramudu, K., & D.Masthan, (). An Efficient Control Strategy for Three-PhaseInverter in Distributed Generation. International Journal of Innovative Research in Technology (IJIRT), 2(7), 491–497.

Related Articles