Comparative Study on an RC Frame Building For Various Seismic Zones

  • Unique Paper ID: 169340
  • Volume: 11
  • Issue: 6
  • PageNo: 681-685
  • Abstract:
  • Any structure must undergo a structural study as well as an earthquake or seismic analysis before construction can begin. Seismic analysis, also known as earthquake response analysis, involves estimating a structure's behaviour when exposed to seismic activity. A variety of seismic data is required to perform the seismic analysis of the structures. In this study, seismic analysis of a structural system is used to determine the storey drift and base shear induced by the applied loads on a residential G+4 RC frame building using the STAAD. Pro Connect Edition software and the structure are engineered by IS 1893:2016(Part 1). The main aim of this study is to compare total displacements, storey drifts, and the base shear of the G+4 RC frame building for the various seismic zones as per Indian standard code IS 1893:2016(Part 1). It is determined that the storey drifts and base shear is increasing from Zone II to Zone V.

Copyright & License

Copyright © 2025 Authors retain the copyright of this article. This article is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

BibTeX

@article{169340,
        author = {Shejal Jain and Rakesh Grover},
        title = {Comparative Study on an RC Frame Building For Various Seismic Zones},
        journal = {International Journal of Innovative Research in Technology},
        year = {2024},
        volume = {11},
        number = {6},
        pages = {681-685},
        issn = {2349-6002},
        url = {https://ijirt.org/article?manuscript=169340},
        abstract = {Any structure must undergo a structural study as well as an earthquake or seismic analysis before construction can begin. Seismic analysis, also known as earthquake response analysis, involves estimating a structure's behaviour when exposed to seismic activity. A variety of seismic data is required to perform the seismic analysis of the structures. In this study, seismic analysis of a structural system is used to determine the storey drift and base shear induced by the applied loads on a residential G+4 RC frame building using the STAAD. Pro Connect Edition software and the structure are engineered by IS 1893:2016(Part 1). The main aim of this study is to compare total displacements, storey drifts, and the base shear of the G+4 RC frame building for the various seismic zones as per Indian standard code IS 1893:2016(Part 1). It is determined that the storey drifts and base shear is increasing from Zone II to Zone V.},
        keywords = {Seismic analysis, seismic zones, RC frame, STAAD. Pro Connect Edition.},
        month = {November},
        }

Cite This Article

  • ISSN: 2349-6002
  • Volume: 11
  • Issue: 6
  • PageNo: 681-685

Comparative Study on an RC Frame Building For Various Seismic Zones